Use Any Combination
of Small Holes
*Maximum recommended load at 10.6 psi [73 kpa] roof loading. Contact project or roofing
engineer for maximum allowable load on individual project roof system.
*All loads are assumed to be uniformly distributed.
ERICO does not recommend the use of CADDY PYRAMID TF series supports on sloped
rooftops with more than 1/12 pitch unless there is a structural attachment of the supports
to the roof structure.
R
Installation steps:
Sweep off loose gravel, if gravel exists.
1.
Consult manufacturer of existing or new roofing system to
2.
determine what type of isolation pads are required by their
roofing system.
3. After pads are installed, place bases on pads.
4. Place pipe in desired location on support.
5. Push clamp down through top holes for pipe retention.
1: Align Pipe
and Clamp
2: Push Down Clamp
Against Pipe
Part Number
Article
Number
Description
Pipe OD Range
Max. Number
Clamps
Max. Rec.
Load*
in[mm]
PTF1C PTF2C
LBF[N]
PTF6
360460
Fixed Height Tool-Free Support: 4 In.[101mm] Tall, 5.5 In.[139mm] Long
-
3 1
300[1334]
PTF10
360461
Fixed Height Tool-Free Support: 4 In.[101mm] Tall, 10 In.[254mm] Long
-
5 2
1000[4450]
PTF16
360462
Fixed Height Tool-Free Support: 4 In.[101mm] Tall, 16 In.[406mm] Long
-
7 3
1500[6670]
PTF1C
360484
Tool-Free Rooftop Pipe Clamp: 3/8" - 1" NPS Pipe [10-25 DN Pipe]
0.50[12.7]-1.32[33.4]
- - -
PTF2C
360485
Tool-Free Rooftop Pipe Clamp: 1" - 2" NPS Pipe [15-50 DN Pipe]
0.84[21.3]-2.38[60.3]
- - -
TECHNICAL SUPPORT:
www.erico.com
CFS487_A
INSTRUCTION SHEET
1 OF 2
© 2014 ERICO International Corporation.
CADDY PYRAMID TF Series
Fixed Height Tool-Free Supports
WARNING:
ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at
1.
www.erico.com
and from your ERICO customer service representative.
ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
2.
All instructions must be
completely
followed to ensure proper and safe installation and performance.
3.
Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property
4.
damage, serious bodily injury and death.
Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.
5.
All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
6.
other purpose.
NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified
engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.
R
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - CADDY PYRAMID TF Series

Use Any Combination of Small Holes*Maximum recommended load at 10.6 psi [73 kpa] roof loading. Contact project or roofing engineer for maximum allowab

Seite 2 - CFS487_A

3.20in81.28mm.80in20.32mm Distance Between Pipe LocationsPipe CenterLine Locations6.40in162.56mm.80in20.32mm Distance Between Pipe LocationsPipe Cente

Kommentare zu diesen Handbüchern

Keine Kommentare